Szemészet, 1999 (136. évfolyam, 1-4. szám)

1999-03-01 / 1. szám

136. évfolyam (1999) 45 PÁLCIKA VALASZ X scale : 25 ms / div. OD b-wave at 68.0 ms Amplitude: 367.8 uV a-wave at 22.0 ms Amplitude: 31.2 uV OS b-wave at 75.5 ms Amplitude: 479.4 uV a-wave at 10.5 ms Amplitude: -19.7 uV Department of Ophthalmology POTE / Pecs MAX SCOTOPIKUS VALASZ X scale : 25 ms / div. OD b-wave at 50.0 ms Amplitude: 793.0 uV a-wave at 16.0 ms Amplitude: 397.9 uV OS b-wave at 46.5 ms Amplitude: 722.7 uV a-wave at 16.0 ms Amplitude: 387.2 uV Department of Ophthalmology POTE / Pecs 30 Hz CSAP VALASZ X scale : 25 ms / div. b-wave at 26.5 ms Amplitude: 250.0 uV a-wave at 16.0 ms Amplitude: 41.5 uV b-wave at 27.0 ms Amplitude: 249.0 uV a-wave at 13.5 ms Amplitude: 74.2 uV A görbepárok felső tagja a jobb, az alsó a bal oldali szemet jellemzi. A pálcika válasz (bal felső görbepár) egy széles pozitív hullám. A maximális scotopicus válasz (jobb felső görbepár) “a"-hulláma a fotoreceptor-rétegben generálódik, a “b”-hullám a bipoláris és a Miiller-sejtrétegből ered. A “b”-hullám amplitúdója több mint kétszerese az “a”-hulláménak. Az oszcillatorikus potenciálok a belső retinarétegek működését jellemzik. A photopicus válaszok (bal alsó görbepár) látenciája rövid, amplitúdója kisebb, alig 1/3-a a scotopicus válaszokénak. 30 Hz-es ingerlésre már csak a csapok reagálnak (jobb alsó görbepár). PÁLCIKA VALASZ X scale : 25 ms / div. OD b-wave at 82.0 ms Amplitude: 40.0 uV a-wave at 18.5 ms Amplitude: 4.9 uV OS b-wave at 78.5 ms Amplitude: 50.3 uV a-wave at 25.5 ms Amplitude: 12.2 uV Department of Ophthalmology POTE / Pecs MAX SCOTOPIKUS VALASZ X scale: 25 ms/div. OD b-wave at 61.5 ms Amplitude: 576.7 uV a-wave at 19.5 ms Amplitude: 290.0 uV OS b-wave at 58.5 ms Amplitude: 580.1 uV a-wave at 18.5 ms Amplitude: 285.2 uV Department of Ophthalmology POTE / Pecs PHOTOPIKUS VALASZ X scale : 25 ms / div. OD b-wave at 50,5 ms Amplitude: 515.6 uV a-wave at 19.0 ms Amplitude: 198.2 uV OS b-wave at 49.0 ms Amplitude: 460.4 uV a-wave at 19,0 ms Amplitude: 132.8 uV Department of Ophthalmology POTE / Pecs 30 Hz CSAP VALASZ X scale : 25 ms / div. OD b-wave at 66.5 ms Amplitude: 190.4 uV a-wave at 18.5 ms Amplitude: 57.8 uV OS b-wave at 67.5 ms Amplitude: 254.6 uV a-wave at 17.5 ms Amplitude: 60.0 uV Department of Ophthalmology POTE / Pecs 3. ábra: A 13 éves lánybeteg ERG görbéje. A pálcikaválaszok kioltottak, a maximális scotopicus válaszok látenciája megnyúlt, az oszcillatorikus potenciálok hiányoznak. A photopicus válaszok látenciája megkésett, amplitúdójuk a maximális scotopicus válaszokéval azonos nagyságú, a normális két­­háromszorosa. A hullámalak a maximális scotopicus válaszokéval azonos. A 30 Hz-es csapválaszok mérsékelten csökkentek. Kékcsap-túlsúly szindróma

Next

/
Oldalképek
Tartalom