Fogorvosi szemle, 1997 (90. évfolyam, 1-12. szám)

1997-10-01 / 10. szám

25, 273,1992. - 12. Roda, R. S., Gutman, J. L.: Reliability of reduced air pressure methods used to assess the apical seal. Int. Endod. J. 28, 154, 1995. - 13. Scott, A C., Vire, D. E., Swanson, R.: An evaluation of the Thermaphil endodontic obturation technique. J. Endod. 18, 340, 1992. - 14. Sen, B. H., Piskin, B., Borán, N.: The effect of tubular penetration of root canal sealers on dye microleage. Int. Endod. J. 29, 23, 1996. — 15. Stewart, G. G.: A comparative study of three root canal sealing agents. Oral. Surg. Oral Med. Oral Pathol. 11, 1029, 1958. - 16. Thomson, S. A, Al-Omari, M. A O., Dummer, P. M. H.: Assessing the shape of root canals: an in vitro method using microradiology. Int Endod. J. 28, 61, 1995. — 17. Van der Berg, H. R., Ten Seldom, C. A., Van der Gulik, P. S.: Compressible laminar flow in a capillary. Journal of Fluid Mechanics. 246, 1, 1993. - 18. Vertucci, F. J. : Root canal anatomy of the human permanent teeth. Oral Surg. 58, 589, 1984. - 19. Wu, M. K, Wesselink, P. R.: Endodontic leakage studies reconsidered. Part 1. Methodology, application and relevance. Int. Endod. J. 26, 37, 1993. - 20. Wu, M. K, De Gee, A. J., Wesselink, P. R., Moorer, W. R.: Fluid transport and bacterial penetration along root canal fillings. Int. Endod. J. 26, 203, 1993. - 21. Wu, M. K, De Gee, A J., Wesselink, P. R.: Fluid transport and dye penetration along root canal fillings. Int. Endod. J. 27, 233, 1994. - 22. Wu, M. K, Wesselink, P. R., Boersma, J.: A 1-year follow-up study on leakage of four root sealers at different thicknesses. Int. Endod. J. 28,185,1995. Tőkés, L., dr. Juhász, A., dr. Dobó Nagy, Cs.: A comparative micro­leakage study of two root canal sealers A quantitative longitudinal study was carried out to compare the amount of microleakage using two different types of root canal sealers on straight and curved root canals. Microleakage was measured just after the setting of the sealer, one month and three months after that using fluid transport model. One month follow up results showed that in straight root canals both the ZOE containing Pulp Canal Sealer and the Cal­ciumhydroxide containing Sealapex sealers produced similar microleakage values to that values measured just after the sett­ing of materials. One month follow up measurement resulted higher values in curved canals comparing to the straight ones in case of both the tested materials. Three months follow up meas­urement demonstrated worse results in the Sealapex groups than the Pulp Canal Sealer groups. With loglinear statistical analysis the following interactions were proved between vari­ables: root canal form/microleakage, root canal form/time laps, and material/microleakage/time laps. Results of the present study are in good agreement with con­clusions of recently published other studies, namely Calciumhyd­roxide containing sealers resulted in higher microleakages than ZOE containing sealers. „Köszönetünket fejezzük ki az Intermetallion Kft.-nek, hogy a kísérletben alkalmazott csatornamegmunkáló eszközöket és gyökértömő anyagokat rendel­kezésünkre bocsátotta. Ez a munka az OTKA (T022455) támogatásával ké­szült.” 306

Next

/
Thumbnails
Contents