Hidrológiai Közlöny 2006 (86. évfolyam)
3. szám - Kaposvári Kázmér: Effect of the intervening ozonizing and Biologie Activated Carbon treatmant to drinking water produced by water supply intake at the River Tisza Szolnok
KAPOSVÁRI K.: Effect of the intervening ozonizing and BAC treatment 29 available in the sand filters which condition facilitates the development of biological systems being concurrent or just the opposite, cooperating with the BAC. When the ozonization was stopped for a 24 days period, after around 5-6 days the organic matter portion adsorbed on the sand filter had reduced to 15 %. At the same time, the residual COD of the active carbon treated water increased to 1,1-1,2 mg/1. The lowest values for the residual AOC were achieved during the stabilized combined operation of the ozonizationsand filtering-active carbon treatment system (~ 20-30 (igC/L). This is important for the biological stability and the proper operation of the distribution network. Summary The potable water for Szolnok city and seven surrounding settlements is supplied from the Szolnok Surface Water Plant using the water from Tisza river directly. The contamination of the Tisza water and the insufficient treatment process of the purification plant resulted in permanent taste, odor, toxicological and biological stability problems. The taste and odor effects created constant consumer complaints. In 1998 the treatment facilities were amended by an interfacial ozonization process - installed after the flocculation - by GAC adsorbers and chlorine-dioxide post-sterilization units. During the 6 years operation period of the enhanced treatment capacity plant no consumer complaint was received. The taste and odor problems stopped. The residual organic matter content in the treated water is COD ~ 0,8 mg/L and AOC < 40 pg/L, which is favorable from the point of view of the network stability and the formation of chlorination byproducts. The parameters - THM < 5 pg/L and AOX < 30 pg/L - of the discharged water satisfy the requirements against the water quality. Bibliography Nagy G. - Hegedűs H.: Szolnoki Felszíni Vízmű- Vízminőség javítás. Tanulmány MÉLYÉPTERV 1987. 50. 1310-31/02. (Szolnok Surface Water Plant - Water quality enhancement. Study) Palicska J. : Ozonos ivóvíz kezelés, fertőtlenítés, íz és szagjavítás, mikroszennyező eltávolítás. Elő- és utóózonozási kisüzemi kísérletek a Szolnoki Felszíni Vízműnél. Kutatási részjelentés 1989. Szolnok megyei Víz- és Csatornaművek Vállalat. (Ozone treatment of potable water, sterilization, taste and odor improvement, micro contaminant removal. Pre- and post-ozonization semiplant experiments at the Szolnok Surface Water Plant. Research report.) Őllős G: Vízellátás - Csatornázás Közegészségügyi ismeretei. Budapest, 2000 Víztisztítás 377-435. (Public sanitary knowledge of water supply - sewerage systems). Golterman H. L. (1962): Mineralization of Algae under sterile conditions or by Bacterial Breakdown. Verh. Int Ver Limnol 15. 544, Bermann D. el al. (1988): Inactivation of particle-associated coliformes by chlorine and monochloramine. Apl. and Environ. Microbiology 54 (2). 507-512 Kreft P. et al. (1985): Converting From Chlorine to Chloramines: A case study. Jawwa. 77./1 J 38.-45 Kárpáti Z. - Palicska J.. Humin frakciók - mint kloroform prekurzorok - klórozás alatti viselkedésének tanulmányozása Box-Wilson módszerrel tervezett kísérletek alapján. Hidrológiai Közlöny 1981. 6. 262-268. (Study on the behavior of humic fractions - as chloroform precursors - during chlorination with the Box-Wilson method based experiments.) Makiéit S. - Dinya Z.: Ivóvíz és felszíni vizek szerves szennyezőinek vizsgálata. 1-2 Kötet. Kutatási jelentés. KLTE Szerves Kémia Tanszék 1988. (Monitoring of the organic contaminants in the potable and surface waters. Research report.) Kaposvári K.: Vízminőségi problémák, és a technológiai fejlesztések kapcsolata a Szolnoki Felszíni Vízmüvei. VÍZMŰ PANORAMA. 4. 22-25, 2000 (The interrelation of the water quality problems and the process enhancement at the Szolnok Surface Water Plant.) Palicska J. - Csépay F. - Káda GY.: A Tisza vízének ipari eredetű szennyezettsége Szolnok megyében. Zárójelentés. DAB Környezetv. Munka Bizottság. Nyíregyháza. 1983.11.26. (Industry originated contamination of the Tisza water in Szolnok county. Final report.) Chedal J. (1982): Ozone Technology and its Practical Applications. ANN. ARB. SCIENCE PUBUSHHERS Inc. Ann. Arbor. MI. Chedal J. (1985): Ozone for Drinking Water Treatmens. In Handbook of Ozone Technology and Applications Vol II. Ed. : Rice R. G Netzer. Butterworth Publishers, Stoncham, MA Glaze W. H. el al. (1990): Evaluating Oxidants for the Removal of modell taste and odor compounds from a municipial Water Suply. Jawwa 87 15/79-84 DugnelJ. P. el al. (1985): Improvement in the Effectivness of ozonation of Drinking Water Through the use of Hydrogen Peroxid. Ozone Sei. Engrg 7. 13/241-258 Magyar P-né - Palicska J. - Süveges Gy. - Kaposvári K.. Vízminőségjavító fejlesztések hatásai a Szolnoki Felszíni Vízmű ivóvíz minőségére. M.H.TXXI. Országos Vándorgyűlés, Szolnok. 2003. július 2-3. - CD dokumentum (The effect of water quality enhancements on the potable water from the Szolnok Surface Water Plant.) Claze W. H. (1989): Evaluation of ozonation By-Products from two California Surface Waters. Jawwa 81/8/66-73 Lalezary S. et al. (1986): Oxidation of five Earthy - Musty Taste and Odor Compounds. Jawwa 78/3/62 Anselme C. at al. (1988): Effect of Ozone on Taste and Odors. Jawwa 80/10/45 Van der Cooij D. (2000): Biological stability: A Multidimensional Quality Aspect of Treated Water. Water, Air and Soil Poll. 123.25A fázisközi ózonozás és BAC kezelés hatása a Tisza folyóra települt Szolnoki Felszíni Vízinű által előállított ivóvíz minőségére Kaposvári Kázmér Kivonat: A Tisza folyó magyarországi szakaszán telepített 45000 m 3/d névleges teljesítményű Szolnoki Felszíni Vízmű 112000 lakos ivóvíz ellátását biztosítja. A szolgáltatott ivóvíz minősége korábban íz-szag, toxikus szerves mikroszennyezők és biológiai stabilitás tekintetében kifogásolt volt. 1998-ban egy vízminőség-javító program keretében 6 kg/h teljesítményű fázisközi ózonozó - 16 perc tartózkodási idejű nyitott GAC adszorber és 2,5 kg/h teljesítményű klórdioxid utófertötlenítő létesült. Az aktívszén adszorbereknél kb. 3 hónap alatt állandósult BAC üzemmód alakult ki. A derítés —* ózonozás —» gyors homokszűrés —> GAC/BAC adszorpció —> utófertőtlenítés technológia a Szolnoki Felszíni Vízműnél is megoldotta a korábbi ivóvíz-minőségi problémákat. A technológia szükség szerint a növelt teljesítményi oxidáció (advanced oxidation processes) és a nanoszürés irányába tovább fejleszthető. Kulcsszavak: vízminőség, oxidatív stabilizálás, Tisza folyó.