Fogorvosi szemle, 1999 (92. évfolyam, 1-12. szám)

1999-06-01 / 6. szám

racci, G., Mori, G., Bazzucchi, M.: Marginal seal and biocompatibility of a fourth-ge­neration bonding agent. Dent. Mater. 11, 343, 1995. - 4. Kaán B., Eichner, K.: Indi­­rekt módszerrel készült, 17-28 éve viselt aranyinlayk széli záródásának vizsgálata különböző módszerekkel. Fogorv. Szle. 89, 339, 1996. - 5. Keller A., Fazekas A., Rosi­­uall L.: Fémvázalapú esztétikus betétek széli záródásának értékelése. Fogorv. Szle. 89, 183, 1996. — 6. Krejci, I., Besek, M., Lutz, F.: Clinical and SEM study of Tetric resin composite in posterior teeth: 12-month results. Am. J. Dent. 7, 27, 1994. — 7. Obádovics J. GY.: Valószínűségszámítás és matematikai statisztika. Scolar Kiadó, Budapest, 1997. 124—131. — 8. Retief D. H. et al.: Evaluation of the Syntac bonding system. Am. J. Dent. 6, 17, 1993. - 9. Roulet, J. F.: Margin quality: criteria and tech­niques for assessment. Anusavice, K. J. (ed.): Quality Evaluation of Dental Restora­tions Quintessence Publishing Co., Chicago, 1989. 223-242. — 10. Sturdevant, С. M. et al.: The Art and Science of Operative Dentistry. Mosby Year Book, St. Louis, 1995. 280. — 11. Tay, F. R. et al.: Variability in microleakage observed in a total-etch wet­bonding technique under different handling conditions. J. Dent. Res. 74, 1168, 1995. Dr. Székely, M., dr. Bocskai, I.: Scanning electron microscopic examination of marginal fitting of composite filings The aim of the present in vitro study was to evaluate the mar­ginal gap formation of composite restorations. Class V. cavities were prepared on the buccal surfaces of 30 human teeth and re­stored with Prime & Bond 2.1 (Spectrum TPH and Syntac Sin­gle-Component) Tetric. The specimens were examined by scan­ning electron microscope (SEM). By measurement of marginal: gap dimensions this study aimed at comparing the marginal fit­ting and bonding potentials of current generation composite: resins and adhesive systems. The data were analyzed by a two­­sample t-test. No significant differences were detected (p<0,001) between the two groups. The specimens showed very narrow gaps of 0-5 pm thickness and 60% of the composite fillings pre­sented gap-free attachment to enamel. These results may have significant implications related to clinical longevity of composite restorations. Köszönetét mondunk Dr. Virág Szabolcs egyetemi tanárnak és Farsang József mérnöknek, hogy lehetővé tették a cikkben ismertetett vizsgálat megvalósítását a budapesti Haynal Imre Egészségtudományi Egyetemen. 190

Next

/
Oldalképek
Tartalom