66 Szemészet Supplementum I. Results: Measurement values obtained by TD-OCT were significantly lower than the ones obtained by SD-OCT (p<0.001) in all nine macular subfields. The differences between the values obtained by the two different protocols of SD-OCT were not significant in 83.3% of all the data. Relative standard deviations (RSD) ranged from 0-20.8% among all measurements. Average RSD of TD-OCT and SD-OCT with c512 and c200 protocol were 1.857±2.94, 0.739±0.65 and 0.855±1.75 respectively. Conclusion: By using any of the two protocols of SD-OCT we could observe better reproducibility than with TD-OCT. Using SD-OCT, significantly higher measurement values could be obtained at any of the macular subfields than when measured with TD-OCT. Using different OCT machines we get significantly different retinal thickness values therefore care needs to be taken when comparing data. A látásteljesítmény mérése - A távoli látóélesség mérésére alkalmas optotypok Sebestyén Ibolya Világ Világossága Alapítvány, Pécs A látószerv funkciója a külvilág információinak közvetítése, mely információáramlás dominánsan (>80%) vizuális úton történik. Ezen funkció mérésének számos módja van. de talán a legvalósabb erre a látóélesség szubjektív meghatározása. Azért igaz ez. mert egybeesik azzal, amit a páciens megél, használ. Ahhoz azonban, hogy megbízhatóan összehasonlíthatóak legyenek a különböző időben, helyen és személyektől felvett visusértékek, szükséges, hogy az erre használt optotypok nemzetközileg standardizáltak, elfogadottak legyenek. A primer optotypként definiált Landolt-gyűrü minimum seperabilét mérő értékét néhány - az előbbinél könnyedebben használható - optotyp jól megközelíti, és nemzetközileg kiterjedten használják mind szűrővizsgálatokon, mind a különböző kórokok következtében létrejött átmeneti vagy tartós látóélesség-változásnak a kifejezésére. A Snellen-villa, a STYCAR teszt vagy az Ábrás tábla (Lea-teszt) évtizedek óta használt és elfogadott világszerte. Előadásomban ezek validitásáról. használatukkal szerzett tapasztalatimról kívánok beszélni. Measuring visual function - Optotypes facilitating the measurement of long distance visual acuity Ibolya Sebestyén Foundation Light of the World, Pécs We receive information about our surroundings predominantly (>80%) by visual input. The function of the visual organ is to deliver this information from the outside world to us. There are multiple ways to determine the function of the visual organ, however, determining the subjective visual acuity might be the most useful one. Subjective visual acuity is the measure that tells us about the patient's actual visual experience. In order to make visus measurements - taken at different places and times and from different patients - comparable, it is necessary to use internationally standardized and accepted optotypes. The primary standard optotype is the Landolt C, however, its ability to determine the minimum separable acuity is not significantly superior to multiple other, more user-friendly optotypes. The Snellen E-test, the STYCAR test, and the Lea test are all well respected tests and have been in world-wide use for several decades. They can be used both in screening tests and in following up temporary or permanent visus changes of diverse origin. In the presentation I would like to share my experience about the validity and usage of these latter three optotypes. Előadáskjvonatok / Abstracts