Fogorvosi szemle, 2020 (113. évfolyam, 1-4. szám)

2020-12-01 / 4. szám

FOGORVOSI SZEMLE113. évf. 4. sz. 2020.n 138 of a screw-retained restoration avoiding the facial access hole: a clinical report. The Journal of prosthetic dentistry 2015; 114 (5): 621–624. https://doi.org/10.1016/j.prosdent.2015.06.007 16. GOODACRE CJ, BERNAL G, RUNGCHARASSAENG K, KAN JY: Clinical complications with implants and implant prostheses. The Journal of prosthetic dentistry 2003; 90 (2): 121–132. https://doi.org/10. 1016/S0022-3913(03)00212-9 17. GOODACRE CJ, KAN JY, RUNGCHARASSAENG K: Clinical complications of osseointegrated implants. The Journal of prosthetic dentistry 1999; 81 (5): 537–552. https://doi.org/10.1016/S0022-3913(99) 70208-8 18. GREENSTEIN G, CARPENTIERI J, CAVALLARO J: Open contacts adjacent to dental implant restorations: Etiology, incidence, consequenc­es, and correction. The Journal of the American Dental Associ­ation 2016; 147 (1): 28–34. https://doi.org/10.1016/j.adaj.2015. 06.011 19. JING L, XIN X, GUANGSHUI J, YANJIN G, HAIYUN H, JIN L, et al: Three­dimension finite element analyses of interior stress of two kinds of Replace implant. West China Journal of Stomatology 2011; 29 (5). https://doi.org/10.1155/2016/4867402 20. KAWAHARA H, KAWAHARA D, HAYAKAWA M, TAMAI Y, KUREMOTO T, MATSUDA S: Osseointegration under immediate loading: biome­chanical stress-strain and bone formation-resorption. Implant dentistry 2003; 12 (1): 61–68. https://doi.org/10.1097/01.ID. 0000034394.75768.E3 21. KREISSL ME, GERDS T, MUCHE R, HEYDECKE G, STRUB JR: Techni­cal complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clinical oral implants research 2007; 18 (6): 720–726. https://doi.org/10.1111/j.1600-0501.2007.01414.x 22. LEVINE RA, CLEM D, WILSON T, HIGGIBOTTOM F, SOLNIT G: Multicenter Retrospective Analysis of the ITI Implant System Used for Single-Tooth Replacements: Results of Loading for 2 or Mare Years. International Journal of Oral Maxillofacial Implants 1999; 14: 516–520. 23. LIU Y, WANG J: Influences of microgap and micromotion of im­plant-abutment interface on marginal bone loss around implant neck. Archives of Oral Biology 2017; 83: 153–160. https://doi.org/ 10.1016/j.archoralbio.2017.07.022 24. MAEDA Y, HORISAKA M, YAGI K: Biomechanical rationale for a sin­gle implant-retained mandibular overdenture: an in vitro study. Clinical oral implants research 2008; 19 (3): 271–275. https://doi. org/10.1111/j.1600-0501.2007.01425.x 25. MAIRGÜNTHER RN, G: Das Dichtigkeits-verhalten des Verbind­ungssystems beim zweiphasigen Ankylos-Implantat [The tight­ness behavior of the connection system of the 2-phase Anky­los implant]. Zeitschrift für Zahnärztliche Implantologie 1992; 5: 50–53. 26. MENG JC, EVERTS JE, QIAN F, GRATTON DG: Influence of connec­tion geometry on dynamic micromotion at the implant-abutment interface. International Journal of Prosthodontics 2007; 20 (6). 27. MERZ BR, HUNENBART S, BELSER UC: Mechanics of the implant­abutment connection: an 8-degree taper compared to a butt joint connection. International Journal of Oral Maxillofacial Implants 2000; 15 (4). 28. MÖLLERSTEN L, LOCKOWANDT P, LINDÉN L-Å: Comparison of strength and failure mode of seven implant systems: an in vitro test. The Journal of prosthetic dentistry 1997; 78 (6): 582–591. https://doi. org/10.1016/S0022-3913(97)70009-X 29. NEVINS M, LANGER B: The successful application of osseointegrat­ed implants to the posterior jaw: a long-term retrospective study. International Journal of Oral Maxillofacial Implants 1993; 8 (4). 30. PRITHVIRAJ D, MULEY N, GUPTA V: The evolution of external and internal implant-abutment connections: A review. International Dental Research 2012; 2 (2): 37–42. https://doi.org/10.5577/ intdentres.2012.vol2.no2.3 31. SHAFIE HR: Clinical and laboratory manual of dental implant abutments: John Wiley & Sons, 2014. https://doi.org/10.1002/ 9781118928547 32. SZMUKLER-MONCLER S, SALAMA H, REINGEWIRTZ Y, DUBRUILLE J: Timing of loading and effect of micromotion on bone-dental im­plant interface: review of experimental literature. Journal of bio­medical materials research 1998; 43 (2): 192–203. https://doi. org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3. 0.CO;2-K 33. TANG C-B, LIU S-Y, ZHOU G-X, YU J-H, ZHANG G-D, BAO Y-D, et al: Nonlinear finite element analysis of three implant-abutment in­terface designs. International journal of oral science 2012; 4 (2): 101. https://doi.org/10.1038/ijos.2012.35 34. VARTHIS S, RANDI A, TARNOW DP: Prevalence of Interproximal Open Contacts Between Single-Implant Restorations and Adja­cent Teeth. International Journal of Oral Maxillofacial Implants 2016; 31 (5). https://doi.org/10.11607/jomi.4432 35. WADHWANI C: Understanding implant abutment connection inter­faces. Decisions in Dentistry 2018: 31–34. 36. WADHWANI CPK: Cementation in Dental Implantology. Springer- Verlag Berlin Heidelberg, Berlin, 2015. https://doi.org/10.1007/ 978-3-642-55163-5 37. WILSON TG, JR: The positive relationship between excess ce­ment and peri-implant disease: a prospective clinical endoscopic study. Journal of periodontology 2009; 80 (9): 1388–1392. https:// doi.org/10.1902/jop.2009.090115

Next

/
Thumbnails
Contents