Fogorvosi szemle, 1999 (92. évfolyam, 1-12. szám)
1999-02-01 / 2. szám
Oral and Max. Fac. Surg. 55, Suppl. 3., 92. August, 1997. - 4. Kreusch, T., Hezel, J., Fleinpr, B.: Die klinische Anwendung des Denta-CT in der radiologischen Diagnostik. Dtsc'h. Z. Mund Kiefer Gesichtgschir. 17, 243, 1993. - 5. Luka, B., Berchtelsbauer, D., Gellrich, N. C., Köriig, M.: 2D and 3D CT reconstructions of the facial skeleton: an unnecessary option or a diagnostic pearl? Int. J. Oral Maxillofac. Surg. 24, 76, 1995. — 6. Ono, J., Ohura, T., Narumi, E., Kawashima, K., Matsuno, 1., Nakamura, S., Ohhata, N: Three-dimensional analysis of craniofacial bones using three-dimensionalcomputer tomography. J. Craniomaxillofac. Surg. 20, 49, 1992. — 7. Suba Zs., Szabó Gy., Haris A., Divinyi T., Martonffy K. : Tapasztalatok a HTR polymer klinikai alkalmazásával sinus elevatio, human szövettani vizsgálatok Fogorvosi Szemle. 84, 75, 1991. — 8. Szabó, G., Suba, Zs, Divinyi, T., Haris, A.: HTR polymer and sinus elevation: a human histologic evaluation. J. of Long-Term Effects of Med. Impl. 2, 80, 1992. — 9. Szabó, G., Suba, Zs.., Barabás, J.: Use of Bioplant HTR Synthetic bone to eliminate major jawbone defects: long-term human histological examinations. J. of Cran. Maxillofac. Surg. 25, 63, 1997. — 10. Vannier, M. V., Marsh, J. L., Warren, J. O.: Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. Radiology. 150, 179, 1984. - Wicht, L., Moegelin, A., Schedel, II., Pentzold, C., Bier, J., Langer, R., Felix, R.: Dental-CT Studie zur praeoperativen Beurteilung der Kieferatrophie. Aktuelle Radiol. 4, 64, 1994. Szabó Gy., Hrabák К., Gyulai-Gaál, Sz.: 3D CT for planning and contrail of sinus elavation We have performed 3D CT examinations before and after 21 uniand bilateral sinus elevations, immediately prior to loading of the implants and 1 year after the loading. Comparison of the results with those of panoramic and the customary CT examinations yielded the following useful information.- Any possible difference between planning and performance may be controlled.- The fate of biomaterial implanted in the maxillary sinus was followed.- The 3D CT projections providing most information were established (from a superior position downwards; from lateral and posterior positions forwards).- Possible errors can be discovered before the implant is loaded.- The cases in which it is worthwhile to perform this costly examination were determined: surgical complications, documentation, extensive alveolar atrophy etc.- The results of sinus elevation with different bone substitute materials can readily be compared (e.g. autogenous bone + HTR Bioplant on one side, and autogenous bone + Algipore on the other side). 44